Irc Required Attic Access Drawing
The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures.
Irc required attic access drawing. The international codes i codes are the widely accepted comprehensive set of model codes used in the us and abroad to help ensure the engineering of safe sustainable affordable and resilient structures. The rough framed opening of the attic access shall be not less than 22 inches by 30 inches 559 mm by 762 mm for you canucks. 2attic loads may be included in the floor live load but a 10 psf attic load is typically used only to size ceiling joists adequately for access purposes. However if the attic is intended for storage the attic live load or some portion should also be considered for the design of other elements in the load path.
There you ll see that an access opening is all that is specified not stairs. Attic area exceeds 30 square feet and. Current international residential code irc 12 13 section r807 attic access. The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process.
The 2009 and 2015 irc verbiage is similar and still applicable. The florida building code fbc and international residential code irc both require a minimum of one attic access opening for homes with combustible such as wood roof construction if the attic space meets these two criteria. The international code council icc is a non profit organization dedicated to developing model codes and standards used in the design build and compliance process. Attics that meet the size and ceiling height criteria of the habitable attic definition in chapter 2 are considered habitable.
Minimum vertical height of 30 inches measured from the top of the ceiling framing members to the bottom of the roof framing members. See section m1305 1 3 for access requirements where mechanical equipment is located in attics. Please be aware of the definition and egress requirements of a habitable attic as it relates to dwellings built from the 2012 irc. When the access is located in a ceiling minimum unobstructed headroom in the attic space shall be 30 inches 762 mm at some point above the access measured vertically from the bottom of ceiling framing members.
This section makes it very clear. Attic access requirements after getting help from an internachi inspector we ve come up with irc r807 1 attic access. You will also see that for smaller attic areas no access is required whatsoever in my view some access to all such limited space areas is desirable to permit visual inspection for leaks. See the california mechanical code for access requirements where mechanical equipment is located in attics.
2009 international residential code irc topic 2006 irc 2009 irc page 469 access hatches none n1102 2 3 access hatches and doors access doors from and doors.